Pressure |
Regulators |
|
|
|
|
|
High Flow/Pressure
Reducing Regulator 44-1300 |
|
High Flow/Low Pressure
Regulator DH Series |
|
|
  |
pressure rating per
criteria of |
|
 |
maximum 300 PSIG in /
0-250 PSIG out |
|
ANSI/ASME B31.3. |
|
spring loaded or
dome loaded / high |
|
|
maximum 3750 PSIG
(brass), |
|
sensitivity. |
|
|
4500 PSIG (SST) in
ranges: |
|
ambient operating . . -20° F to +165° F |
|
|
0 - 1500 PSIG out pressure reducing. |
|
Flow capacity . . . . .
. . . . . . Cv = 5.0 |
|
|
flow capacity: |
|
Body, bonnet, back cap
316 SS or |
|
|
1/4” main valve . . . . . . . . . . C v = 0.8 |
|
brass; Diaphragm-Ethylene
Propylene, |
|
|
3/8” main valve . . . . . . . . . . C v = 2.0 |
|
Nylon Reinforced, Gylon® (PTFE). |
|
|
operating temperature -15° F +220° F |
|
Panel mounting option. |
|
|
|
High Flow/Purge Pressure
Reducing Regulator |
|
High Flow/Sensitive
Pressure Regulator 26-2900 |
|
|
 |
maximum 500 & 3000 PSIG
in / ranges |
|
 |
maximum 1000 PSIG control
pressure; |
|
of 0-200 PSIG out pressure reducing. |
|
maximum 1000 PSIG
reference |
|
|
leakage: internal . . .
. . . . bubble-tight |
|
pressure; dome
loaded/negative |
|
|
external . . < 2 X 10-8 atm cc/sec He |
|
bias/back pressure. |
|
|
operating temperature -40° F +165° F |
|
operating temperature 0° F to +165° F |
|
|
flow capacity . . . . . Cv = 1.0 |
|
flow capacity . . . . . . . . . . . . Cv = 2.0 |
|
|
(optional Cv = 1.8) |
|
crack-to-reseat differential: |
|
|
3000 PSIG inlet . . . .
. . . . . . . . . CTFE |
|
0-15 PSIG range . . . . . . . . . . . 3 PSIG |
|
|
500 PSIG inlet . . . . . . . . . . . . Teflon® |
|
0-30 PSIG range . . . . . . . . . . . 5 PSIG |
|
|
|
|
|
|
|
|
|